R30
Bi-Directional Rod Seal
Capable of sealing low to high pressures from both sides with a small footprint. Compact and most economical double-acting rod seal for most bi-directional sealing applications.
Operating Range
Material | Operating Pressure up to | Maximum Pressure up to | Temperature | Surface Speed up to | Fluid, Media Compatability |
---|---|---|---|---|---|
Duralast 4203 | 3,800psi (260bar) | 5,000psi (350bar) | -22°F to 260°F (-30°C to 125°C) | 1.6ft/s (0.5m/s) | mineral oil-based fluids, fire-resistant water-based hydraulic fluids including HFA and HFB, sea water, biodegradable fluids, vegetable oils, bio-diesels, and most modern hydraulic fluids |
Duralast 4403 | 5,000psi (350bar) | 8,000psi (520bar) | -22°F to 260°F (-30°C to 125°C) | 1.6ft/s (0.5m/s) | same as Duralast 4203 |
Duralast 8166 | 2,300psi (160bar) | 3,800psi (260bar) | -4°F to 392°F (-20°C to 200°C) | 3.2ft/s (1.0m/s) | fire-resistant fluids, phosphate esters, mineral oils, greases, and most inorganic acids and chemicals, gasoline and gasoline/alcohol blends, hard vacuum |
Duralast 5101 | 2,300psi (160bar) | 3,800psi (260bar) | -22°F to 212°F (-30°C to 100°C) | 1.6ft/s (0.5m/s) | mineral-oil based hydraulic fluids, silicone greases, petroleum-based oils, water and alcohols |
Duralast 6146 | 2,300psi (160bar) | 3,800psi (260bar) | -30°F to 302°F (-35°C to 150°C) | 2.0ft/s (0.7m/s) | excellent heat and oil resistance, including exposure to such oil additives as detergents, anti-oxidants and anti-wear agents |
Additional standard materials available: High-performance polyurethanes, NBR (Nitrile), FKM, Viton®, HNBR, EPDM, Aflas®, Hytrel®, Silicone, low- and high-temperature, FDA-compliant seal material grades, PTFE, filled PTFE®, engineered thermoplastics and proprietary specialized Duralast™, Duraloy™, and Permachem™ materials. |
|||||
Important Note: Maximum values above depend on extrusion gap, clearances, seal material, media, temperatures, pressures, surface speed, dynamic running surface finish and working environment. Seals cannot be operated at their upper ratings at the same time. Pressure ratings can be increased by reducing clearances. For pressure above specified operating pressure, please contact engineering@ahpseals.com |
Size Table (Inch)
A Rod Diameter | CS Cross-Section | D Groove Diameter | B* Gland Diameter | Tolerance | L Groove Width | C | R1 | R |
||
---|---|---|---|---|---|---|---|---|---|---|
Standard Range | Functional Range | Tolerance | D= | B= | D,B | Tol.+0.008/-0 | min. | max. | max. |
|
0.312 - 0.624" | 0.300 - 1.500" | +0/-0.001 | 0.097 | A + 0.194 | A + 0.024 | +0.001/-0 | 0.087 | 0.080 | 0.015 | 0.006 |
0.625 - 1.624" | 0.560 - 3.500" | +0/-0.002 | 0.143 | A + 0.286 | A + 0.026 | +0.002/-0 | 0.126 | 0.050 | 0.015 | 0.006 |
1.625 - 3.249" | 0.750 - 8.000" | +0/-0.003 | 0.210 | A + 0.420 | A + 0.027 | +0.003/-0 | 0.165 | 0.070 | 0.020 | 0.006 |
3.250 - 5.374" | 1.500 - 10.500" | +0/-0.003 | 0.297 | A + 0.594 | A + 0.029 | +0.003/-0 | 0.248 | 0.100 | 0.040 | 0.008 |
5.375 - 12.999" | 5.000 - 26.500" | +0/-0.004 | 0.403 | A + 0.806 | A + 0.030 | +0.004/-0 | 0.319 | 0.130 | 0.050 | 0.008 |
13.000 - 26.500" | 10.000 - 40.000" | +0/-0.005 | 0.473 | A + 0.946 | A + 0.034 | +0.005/-0 | 0.319 | 0.130 | 0.050 | 0.008 |
> 26.500" | consult with Ahpseals engineering | |||||||||
* Based on using wear rings. For pressure above 3,800psi, please contact engineering for clearances. For rod diameter below 0.475 inch, open or split housing is recommended. Surface finish: rod (A) Ra 4-12µin – Static (D,L) Ra max. 32µin. See Technical Info for more specific information. |
Seal Housing Drawing